Cost-exergy optimisation of linear Fresnel reflectors

Abstract

This paper presents a new method for the optimisation of the mirror element spacing arrangement and operating temperature of linear Fresnel reflectors (LFR). The specific objective is to maximise available power output (i.e. exergy) and operational hours whilst minimising cost. The method is described in detail and compared to an existing design method prominent in the literature. Results are given in terms of the exergy per total mirror area (W/m2) and cost per exergy (US $/W). The new method is applied principally to the optimisation of an LFR in Gujarat, India, for which cost data have been gathered. It is recommended to use a spacing arrangement such that the onset of shadowing among mirror elements occurs at a transversal angle of 45°. This results in a cost per exergy of 2.3 $/W. Compared to the existing design approach, the exergy averaged over the year is increased by 9% to 50 W/m2 and an additional 122 h of operation per year are predicted. The ideal operating temperature at the surface of the absorber tubes is found to be 300 °C. It is concluded that the new method is an improvement over existing techniques and a significant tool for any future design work on LFR systems

Publication DOI: https://doi.org/10.1016/j.solener.2011.09.024
Divisions: College of Engineering & Physical Sciences > School of Engineering and Technology > Mechanical, Biomedical & Design
College of Engineering & Physical Sciences > Sustainable environment research group
College of Engineering & Physical Sciences > School of Infrastructure and Sustainable Engineering > Engineering Systems and Supply Chain Management
Additional Information: NOTICE: this is the author’s version of a work that was accepted for publication in <Journal title>. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in Davies, P & Nixon, J, 'Cost-exergy optimisation of linear Fresnel reflectors', Solar Energy, vol 86, no. 1 (2012) DOI http://dx.doi.org/10.1016/j.solener.2011.09.024
Uncontrolled Keywords: solar thermal collector,linear Fresnel reflector (LFR),linear Fresnel collector,exergy,CSP,Renewable Energy, Sustainability and the Environment,General Materials Science
Publication ISSN: 0038-092X
Last Modified: 18 Nov 2024 08:06
Date Deposited: 24 Apr 2012 11:20
Full Text Link:
Related URLs: http://www.scop ... tnerID=8YFLogxK (Scopus URL)
PURE Output Type: Article
Published Date: 2012-01
Published Online Date: 2011-10-19
Authors: Davies, Philip (ORCID Profile 0000-0003-4783-1234)
Nixon, Jonathan

Download

[img]

Version: Accepted Version


Export / Share Citation


Statistics

Additional statistics for this record