Shu, Xuewen, Sugden, Kate and Bennion, Ian (2010). Single uniform FBG for simultaneous measurement of liquid level and temperature. Measurement science and technology, 21 (9), 094003.
Abstract
In this paper, we propose and demonstrate a novel scheme for simultaneous measurement of liquid level and temperature based on a simple uniform fiber Bragg grating (FBG) by monitoring both the short-wavelength-loss peaks and its Bragg resonance. The liquid level can be measured from the amplitude changes of the short-wavelength-loss peaks, while temperature can be measured from the wavelength shift of the Bragg resonance. Both theoretical simulation results and experimental results are presented. Such a scheme has some advantages including robustness, simplicity, flexibility in choosing sensitivity and simultaneous temperature measurement capability.
Divisions: | College of Engineering & Physical Sciences > School of Computer Science and Digital Technologies > Electronics & Computer Engineering College of Engineering & Physical Sciences |
---|---|
Uncontrolled Keywords: | fiber optics sensors, fiber Bragg gratings, liquid-level sensor |
Publication ISSN: | 0957-0233 |
Last Modified: | 17 Oct 2024 12:14 |
Date Deposited: | 29 Sep 2010 12:05 |
Published Date: | 2010-07-28 |
Authors: |
Shu, Xuewen
Sugden, Kate Bennion, Ian |