Kaye, Stephen B., Surti, Jamila and Wolffsohn, James S. (2023). Average paraxial power of a lens and visual acuity. Scientific Reports, 13 (1),
Abstract
To provide a solution for average paraxial lens power (ApP) of a lens. Orthogonal and oblique sections through a lens of power [Formula: see text] were reduced to a paraxial representation of lens power followed by integration. Visual acuity was measured using lenses of different powers (cylinders of - 1.0 and - 2.0D) and axes, mean spherical equivalent (MSE) of S + C/2, ApP and a toric correction, with the order of correction randomised. A digital screen at 6 m was used on which a Landolt C with crowding bars was displayed for 0.3 s before vanishing. The general equation for a symmetrical lens of refractive index (n), radius of curvature R, in medium of refractive index n1, through orthogonal ([Formula: see text]) and oblique meridians ([Formula: see text]) as a function of the angle of incidence ([Formula: see text]) reduces for paraxial rays ([Formula: see text]) to [Formula: see text]. The average of this function is [Formula: see text] providing a solution of [Formula: see text] for ApP.For central (p = 0.04), but not peripheral (p = 0.17) viewing, correction with ApP was associated with better visual acuity than a MSE across all tested refractive errors (p = 0.04). These findings suggest that [Formula: see text] may be a more inclusive representation of the average paraxial power of a cylindrical lens than the MSE.
Publication DOI: | https://doi.org/10.1038/s41598-023-34010-4 |
---|---|
Divisions: | College of Health & Life Sciences > School of Optometry > Optometry & Vision Science Research Group (OVSRG) College of Health & Life Sciences College of Health & Life Sciences > School of Optometry > Optometry Aston University (General) |
Additional Information: | Copyright © The Author(s) 2023. This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. |
Uncontrolled Keywords: | Applied optics,Medical research,translational research |
Publication ISSN: | 2045-2322 |
Last Modified: | 04 Nov 2024 09:19 |
Date Deposited: | 03 May 2023 08:21 |
Full Text Link: | |
Related URLs: |
https://www.nat ... 598-023-34010-4
(Publisher URL) http://www.scop ... tnerID=8YFLogxK (Scopus URL) |
PURE Output Type: | Article |
Published Date: | 2023-05-02 |
Published Online Date: | 2023-05-02 |
Accepted Date: | 2023-04-22 |
Submitted Date: | 2022-09-01 |
Authors: |
Kaye, Stephen B.
Surti, Jamila Wolffsohn, James S. ( 0000-0003-4673-8927) |