Test-Retest Reliability of Acoustic Emission Sensing of the Knee during Physical Tasks

Abstract

Acoustic emission (AE) sensing is an increasingly researched topic in the context of orthopedics and has a potentially high diagnostic value in the non-invasive assessment of joint disorders, such as osteoarthritis and implant loosening. However, a high level of reliability associated with the technology is necessary to make it appropriate for use as a clinical tool. This paper presents a test-retest and intrasession reliability evaluation of AE measurements of the knee during physical tasks: cycling, knee lifts and single-leg squats. Three sessions, each involving eight healthy volunteers were conducted. For the cycling activity, ICCs ranged from 0.538 to 0.901, while the knee lifts and single-leg squats showed poor reliability (ICC < 0.5). Intrasession ICCs ranged from 0.903 to 0.984 for cycling and from 0.600 to 0.901 for the other tasks. The results of this study show that movement consistency across multiple recordings and minimizing the influence of motion artifacts are essential for higher test reliability. It was shown that motion artifact resistant sensor mounting and the use of baseline movements to assess sensor attachment can improve the sensing reliability of AE techniques. Moreover, constrained movements, specifically cycling, show better inter- and intrasession reliability than unconstrained exercises.

Publication DOI: https://doi.org/10.3390/s22239027
Divisions: College of Engineering & Physical Sciences > School of Engineering and Technology > Mechanical, Biomedical & Design
College of Engineering & Physical Sciences > School of Engineering and Technology
Funding Information: This research was funded by Science Foundation Ireland (SFI) under Grant number 12/RC/2289-P2 (INSIGHT) and in part under Grant numbers 13/RC/2077 (CONNECT) and 16/RC/3918 (CONFIRM) which are co-funded under the European Regional Development. For the purp
Additional Information: Funding Information: This research was funded by Science Foundation Ireland (SFI) under Grant number 12/RC/2289-P2 (INSIGHT) and in part under Grant numbers 13/RC/2077 (CONNECT) and 16/RC/3918 (CONFIRM) which are co-funded under the European Regional Development. For the purpose of Open Access, the author has applied a CC BY public copyright license to any Author Accepted Manuscript version arising from this submission. Publisher Copyright: © 2022 by the authors. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Uncontrolled Keywords: joint health,joint sound,measurement properties,on-body sensor monitoring,repeatability,Analytical Chemistry,Information Systems,Biochemistry,Atomic and Molecular Physics, and Optics,Instrumentation,Electrical and Electronic Engineering
Publication ISSN: 1424-8220
Last Modified: 11 Nov 2024 08:47
Date Deposited: 03 Apr 2023 13:40
Full Text Link:
Related URLs: http://www.scop ... tnerID=8YFLogxK (Scopus URL)
https://www.mdp ... 8220/22/23/9027 (Publisher URL)
PURE Output Type: Article
Published Date: 2022-11-22
Accepted Date: 2022-11-19
Authors: Khokhlova, Liudmila
Komaris, Dimitrios Sokratis (ORCID Profile 0000-0003-4623-9060)
Tedesco, Salvatore
O’Flynn, Brendan

Download

[img]

Version: Published Version

License: Creative Commons Attribution

| Preview

Export / Share Citation


Statistics

Additional statistics for this record