Yazdi, Sina G., Docherty, Paul D., Williamson, Petra N., Jermy, Mark, Kabaluik, Natalia, Khanafer, Adib and Geoghegan, Patrick H. (2021). In vitro pulsatile flow study in compliant and rigid ascending aorta phantoms by stereo particle image velocimetry. Medical Engineering and Physics, 96 , pp. 81-90.
Abstract
The aorta is a high risk region for cardiovascular disease (CVD). Haemodynamic patterns leading to CVD are not well established despite numerous experimental and numerical studies. Most overlook effects of arterial compliance and pulsatile flow. However, rigid wall assumptions can lead to overestimation of wall shear stress; a key CVD determinant. This work investigates the effect of compliance on aortic arch haemodynamics experiencing pulsatility. Rigid and compliant phantoms of the arch and brachiocephalic branch (BCA) were manufactured. Stereoscopic particle image velocimetry was used to observe velocity fields. Higher velocity magnitude was observed in the rigid BCA during acceleration. However, during deceleration, the compliant phantom experienced higher velocity. During deceleration, a low velocity region initiated and increased in size in the BCA of both phantoms with irregular shape in the compliant. At mid-deceleration, considerably larger recirculation was observed under compliance compared to rigid. Another recirculation region formed and increased in size on the inner wall of the arch in the compliant during late deceleration, but not rigid. The recirculation regions witnessed identify as high risk areas for atherosclerosis formation by a previous ex-vivo study. The results demonstrate necessity of compliance and pulsatility in haemodynamic studies to obtain highly relevant clinical outcomes.
Publication DOI: | https://doi.org/10.1016/j.medengphy.2021.08.010 |
---|---|
Divisions: | College of Engineering & Physical Sciences > School of Engineering and Technology > Mechanical, Biomedical & Design College of Engineering & Physical Sciences > Aston Institute of Urban Technology and the Environment (ASTUTE) |
Additional Information: | © 2021, Elsevier. Licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International http://creativecommons.org/licenses/by-nc-nd/4.0/ Funding: Sina G Yazdi was supported during this research by the University of Canterbury Doctoral Scholarship scheme. |
Uncontrolled Keywords: | Aortic arch,Cardiovascular disease,Compliance,Haemodynamics,Particle Image velocimetry,Pulsatile flow,Biophysics,Biomedical Engineering |
Publication ISSN: | 1873-4030 |
Last Modified: | 25 Nov 2024 08:23 |
Date Deposited: | 07 Sep 2021 08:45 |
Full Text Link: | |
Related URLs: |
https://linking ... 350453321001004
(Publisher URL) http://www.scop ... tnerID=8YFLogxK (Scopus URL) |
PURE Output Type: | Article |
Published Date: | 2021-10 |
Published Online Date: | 2021-09-05 |
Accepted Date: | 2021-08-31 |
Authors: |
Yazdi, Sina G.
Docherty, Paul D. Williamson, Petra N. Jermy, Mark Kabaluik, Natalia Khanafer, Adib Geoghegan, Patrick H. ( 0000-0003-1224-0477) |
Download
Version: Accepted Version
License: Creative Commons Attribution Non-commercial No Derivatives
| Preview