The Effect of Cycloplegia on the Ocular Biometric and Anterior Segment Parameters: A Cross-Sectional Study

Abstract

INTRODUCTION: To evaluate the effects of cycloplegia on the biometric components and anterior segment parameters of the eye. METHODS: In this cross-sectional study, changes to axial length (AL), anterior chamber depth (ACD) lens thickness, anterior chamber angle (ACA) and volume, corneal thickness in the pupil center (PC), corneal curvature (CC) and white-to-white (WTW) following cycloplegia induced by tropicamide 1% in 42 eyes of patients aged 23-58 years were assessed. Biometric components and anterior segment parameters were measured using an IOLMaster 700 (Carl Zeiss Meditec, Jena, Germany) and a Pentacam HR (Oculus Optikgeräte GmbH, Wetzlar, Germany), respectively. RESULTS: Significant statistical changes in ACD (increased by 0.06 ± 0.05 mm; p < 0.001), anterior chamber volume (increased by 15.19 ± 10.32 mm 3; p < 0.001), ACA (decreased by 2.18 ± 10.20°; p = 0.029) and lens thickness (decreased by 0.02 ± 0.03 mm; p < 0.001) were observed post-cycloplegia, while the changes in CC, corneal thickness in the PC, WTW and AL were not statistically different (p > 0.05). Also, a significant inferior displacement of the PC along the vertical axes was seen (p = 0.020). CONCLUSION: Cycloplegia resulted in a deeper ACD and thinner lens thickness. These changes should be considered in determining intraocular lens (IOL) power to prevent refractive surprises in cataract surgery and also in the phakic IOL implantation.

Publication DOI: https://doi.org/10.1007/s40123-019-0187-5
Divisions: College of Health & Life Sciences > School of Optometry > Optometry
College of Health & Life Sciences > School of Optometry > Optometry & Vision Science Research Group (OVSRG)
College of Health & Life Sciences
Aston University (General)
Additional Information: © The Author(s) 2019. Open Access - This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (http://creativecommons.org/licenses/by-nc/4.0/), which permits any noncommercial use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
Uncontrolled Keywords: Anterior segment,Biometry,Crystalline lens,Cycloplegia,Ocular components,Ophthalmology
Publication ISSN: 2193-6528
Last Modified: 21 Nov 2024 08:13
Date Deposited: 29 Aug 2019 14:16
Full Text Link:
Related URLs: http://link.spr ... 0123-019-0187-5 (Publisher URL)
http://www.scop ... tnerID=8YFLogxK (Scopus URL)
PURE Output Type: Article
Published Date: 2019-09-01
Published Online Date: 2019-05-03
Accepted Date: 2019-05-03
Authors: Momeni-moghaddam, Hamed
Maddah, Nasim
Wolffsohn, James S. (ORCID Profile 0000-0003-4673-8927)
Etezad-razavi, Mohammad
Zarei-ghanavati, Siamak
Akhavan Rezayat, Amir
Moshirfar, Majid

Download

[img]

Version: Published Version

License: Creative Commons Attribution

| Preview

Export / Share Citation


Statistics

Additional statistics for this record