Mallen, Edward A.H., Gilmartin, Bernard, Wolffsohn, James S. and Tsujimura, Sei-ichi (2015). Clinical evaluation of the Shin-Nippon SRW-5000 autorefractor in adults:an update. Ophthalmic and Physiological Optics, 35 (6), pp. 622-627.
Abstract
Purpose: The Shin-Nippon SRW-5000 is an open view autorefractor that superseded the Canon R-1 autorefractor in the mid-1990s and has been used widely in optometry and vision science laboratories. It has been used to measure refractive error, accommodation responses both statically and dynamically, off-axis refractive error, and adapted to measure pupil size. This paper presents an overview of the original 2001 clinical evaluation of the SRW-5000 in adults (Mallen et al., Ophthal Physiol Opt 2001; 21: 101) and provides an update on the use and modification of the instrument since the original publication. Recent findings: The SRW-5000 instrument, and the family of devices which followed, have shown excellent validity, repeatability, and utility in clinical and research settings. The instruments have also shown great potential for increased research functionality following a number of modifications. Summary: The SRW-5000 and its derivatives have been, and continue to be, of significant importance in our drive to understand myopia progression, myopia control techniques, and oculomotor function in human vision.
Publication DOI: | https://doi.org/10.1111/opo.12254 |
---|---|
Divisions: | College of Health & Life Sciences > School of Optometry > Optometry & Vision Science Research Group (OVSRG) College of Health & Life Sciences > School of Optometry > Optometry College of Health & Life Sciences College of Health & Life Sciences > School of Optometry > Vision, Hearing and Language Aston University (General) |
Additional Information: | This is the peer reviewed version of the following article: Mallen, E. A. H., Gilmartin, B., Wolffsohn, J. S., & Tsujimura, S. (2015). Clinical evaluation of the Shin-Nippon SRW-5000 autorefractor in adults: an update. Ophthalmic and physiological optics, 35(6), 622-627, which has been published in final form at http://dx.doi.org/10.1111/opo.12254. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Self-Archiving. |
Uncontrolled Keywords: | accommodation measurement,Grand Seiko,open-view autorefractor,Shin-Nippon SRW-5000,Ophthalmology,Optometry,Sensory Systems |
Publication ISSN: | 1475-1313 |
Last Modified: | 05 Nov 2024 08:16 |
Date Deposited: | 23 Nov 2015 13:45 |
Full Text Link: |
http://onlineli ... .12254/abstract |
Related URLs: |
http://www.scop ... tnerID=8YFLogxK
(Scopus URL) |
PURE Output Type: | Article |
Published Date: | 2015-11 |
Published Online Date: | 2015-10-23 |
Authors: |
Mallen, Edward A.H.
Gilmartin, Bernard Wolffsohn, James S. ( 0000-0003-4673-8927) Tsujimura, Sei-ichi |