Mousa, Mohammad F., Cubbidge, Robert P., Al-Mansouri, Fatima and Bener, Abdulbari (2014). Evaluation of hemifield sector analysis protocol in multifocal visual evoked potential objective perimetry for the diagnosis and early detection of glaucomatous field defects. Korean journal of ophthalmology, 28 (1), pp. 49-65.
Abstract
CONCLUSIONS: The new HSA protocol used in the mfVEP testing can be applied to detect glaucomatous visual field defects in both glaucoma and glaucoma suspect patients. Using this protocol can provide information about focal visual field differences across the horizontal midline, which can be utilized to differentiate between glaucoma and normal subjects. Sensitivity and specificity of the mfVEP test showed very promising results and correlated with other anatomical changes in glaucoma field loss. PURPOSE: Multifocal visual evoked potential (mfVEP) is a newly introduced method used for objective visual field assessment. Several analysis protocols have been tested to identify early visual field losses in glaucoma patients using the mfVEP technique, some were successful in detection of field defects, which were comparable to the standard automated perimetry (SAP) visual field assessment, and others were not very informative and needed more adjustment and research work. In this study we implemented a novel analysis approach and evaluated its validity and whether it could be used effectively for early detection of visual field defects in glaucoma. METHODS: Three groups were tested in this study; normal controls (38 eyes), glaucoma patients (36 eyes) and glaucoma suspect patients (38 eyes). All subjects had a two standard Humphrey field analyzer (HFA) test 24-2 and a single mfVEP test undertaken in one session. Analysis of the mfVEP results was done using the new analysis protocol; the hemifield sector analysis (HSA) protocol. Analysis of the HFA was done using the standard grading system. RESULTS: Analysis of mfVEP results showed that there was a statistically significant difference between the three groups in the mean signal to noise ratio (ANOVA test, p < 0.001 with a 95% confidence interval). The difference between superior and inferior hemispheres in all subjects were statistically significant in the glaucoma patient group in all 11 sectors (t-test, p < 0.001), partially significant in 5 / 11 (t-test, p < 0.01), and no statistical difference in most sectors of the normal group (1 / 11 sectors was significant, t-test, p < 0.9). Sensitivity and specificity of the HSA protocol in detecting glaucoma was 97% and 86%, respectively, and for glaucoma suspect patients the values were 89% and 79%, respectively.
Publication DOI: | https://doi.org/10.3341/kjo.2014.28.1.49 |
---|---|
Divisions: | College of Health & Life Sciences > School of Optometry > Optometry College of Health & Life Sciences > School of Optometry > Optometry & Vision Science Research Group (OVSRG) College of Health & Life Sciences College of Health & Life Sciences > School of Optometry > Vision, Hearing and Language |
Additional Information: | © 2014 The Korean Ophthalmological Society. This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
Uncontrolled Keywords: | glaucomatous field loss,multifocal visual evoked potential,objective perimetry,standard automated perimetry,General Medicine |
Publication ISSN: | 1011-8942 |
Last Modified: | 12 Dec 2024 08:10 |
Date Deposited: | 24 Jun 2015 13:40 |
Full Text Link: |
http://synapse. ... jo.2014.28.1.49 |
Related URLs: |
http://www.scop ... tnerID=8YFLogxK
(Scopus URL) |
PURE Output Type: | Article |
Published Date: | 2014-01-21 |
Authors: |
Mousa, Mohammad F.
Cubbidge, Robert P. ( 0000-0002-7851-1375) Al-Mansouri, Fatima Bener, Abdulbari |