Mobile app Aston contrast sensitivity test

Abstract

BACKGROUND: Contrast detection is an important aspect of the assessment of visual function; however, clinical tests evaluate limited spatial frequencies and contrasts. This study validates the accuracy and inter-test repeatability of a swept-frequency near and distance mobile app Aston contrast sensitivity test, which overcomes this limitation compared to traditional charts. METHOD: Twenty subjects wearing their full refractive correction underwent contrast sensitivity testing on the new near application (near app), distance app, CSV-1000 and Pelli-Robson charts with full correction and with vision degraded by 0.8 and 0.2 Bangerter degradation foils. In addition repeated measures using the 0.8 occluding foil were taken. RESULTS: The mobile apps (near more than distance, p = 0.005) recorded a higher contrast sensitivity than printed tests (p < 0.001); however, all charts showed a reduction in measured contrast sensitivity with degradation (p < 0.001) and a similar decrease with increasing spatial frequency (interaction > 0.05). Although the coefficient of repeatability was lowest for the Pelli-Robson charts (0.14 log units), the mobile app charts measured more spatial frequencies, took less time and were more repeatable (near: 0.26 to 0.37 log units; distance: 0.34 to 0.39 log units) than the CSV-1000 (0.30 to 0.93 log units). The duration to complete the CSV-1000 was 124 ± 37 seconds, Pelli-Robson 78 ± 27 seconds, near app 53 ± 15 seconds and distance app 107 ± 36 seconds. CONCLUSIONS: While there were differences between charts in contrast levels measured, the new Aston near and distance apps are valid, repeatable and time-efficient method of assessing contrast sensitivity at multiple spatial frequencies.

Publication DOI: https://doi.org/10.1111/cxo.12362
Divisions: College of Health & Life Sciences > School of Optometry > Optometry & Vision Science Research Group (OVSRG)
Additional Information: This is the peer reviewed version of the following article: Kingsnorth, A., Drew, T., Grewal, B., & Wolffsohn, J. S. (2016). Mobile app Aston contrast sensitivity test. Clinical and Experimental Optometry, 99(4), 350–355, which has been published in final form at http://dx.doi.org/10.1111/cxo.12362. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Self-Archiving.
Uncontrolled Keywords: contrast sensitivity,CSV-1000,mobile app,Pelli–Robson chart,repeatability,validity,Ophthalmology,Optometry
Publication ISSN: 1444-0938
Last Modified: 15 Mar 2024 08:12
Date Deposited: 27 Jun 2016 08:50
Full Text Link: http://onlineli ... .12362/abstract
Related URLs: http://www.scop ... tnerID=8YFLogxK (Scopus URL)
PURE Output Type: Article
Published Date: 2016-07
Published Online Date: 2016-06-12
Accepted Date: 2015-09-09
Submitted Date: 2015-05-23
Authors: Kingsnorth, Alec
Drew, Tom
Grewal, Bikramjit
Wolffsohn, James S. (ORCID Profile 0000-0003-4673-8927)

Download

[img]

Version: Accepted Version

| Preview

Export / Share Citation


Statistics

Additional statistics for this record