Developments in contact lens measurement:a comparative study of industry standard geometric inspection and optical coherence tomography

Abstract

Purpose: The aim of this study was to compare a developmental optical coherence tomography (OCT) based contact lens inspection instrument to a widely used geometric inspection instrument (Optimec JCF), to establish the capability of a market focused OCT system. Methods: Measurements of 27 soft spherical contact lenses were made using the Optimec JCF and a new OCT based instrument, the Optimec is830. Twelve of the lenses analysed were specially commissioned from a traditional hydrogel (Contamac GM Advance 49%) and 12 from a silicone hydrogel (Contamac Definitive 65), each set with a range of back optic zone radius (BOZR) and centre thickness (CT) values. Three commercial lenses were also measured; CooperVision MyDay (Stenfilcon A) in −10D, −3D and +6D powers. Two measurements of BOZR, CT and total diameter were made for each lens in temperature controlled saline on both instruments. Results: The results showed that the is830 and JCF measurements were comparable, but that the is830 had a better repeatability coefficient for BOZR (0.065 mm compared to 0.151 mm) and CT (0.008 mm compared to 0.027 mm). Both instruments had similar results for total diameter (0.041 mm compared to 0.044 mm). Conclusions: The OCT based instrument assessed in this study is able to match and improve on the JCF instrument for the measurement of total diameter, back optic zone radius and centre thickness for soft contact lenses in temperature controlled saline.

Publication DOI: https://doi.org/10.1016/j.clae.2016.01.002
Divisions: College of Engineering & Physical Sciences > Aston Institute of Photonics Technology (AIPT)
College of Health & Life Sciences > School of Optometry > Optometry & Vision Science Research Group (OVSRG)
College of Health & Life Sciences
College of Health & Life Sciences > School of Optometry > Vision, Hearing and Language
College of Health & Life Sciences > School of Optometry > Optometry
Additional Information: © 2016, Elsevier. Licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International http://creativecommons.org/licenses/by-nc-nd/4.0/
Publication ISSN: 1476-5411
Last Modified: 22 Apr 2024 07:13
Date Deposited: 08 Feb 2016 12:05
Full Text Link:
Related URLs: https://www.sci ... 0029?via%3Dihub (Publisher URL)
PURE Output Type: Article
Published Date: 2016-08-01
Published Online Date: 2016-01-24
Accepted Date: 2016-01-08
Submitted Date: 2015-08-07
Authors: Coldrick, Benjamin J. (ORCID Profile 0000-0003-0969-7062)
Richards, Colin
Sugden, Kate (ORCID Profile 0000-0001-6323-1082)
Wolffsohn, James S. (ORCID Profile 0000-0003-4673-8927)
Drew, Thomas E.

Export / Share Citation


Statistics

Additional statistics for this record